Permanent Joint Sealing for Facades / Water Tightness, Thermal and Acoustic Insulation

Facade joints, such as joints between cladding panels or around windows and doors, are often sealed to avoid water ingress, heat loss and promote acoustic insulation. Effisus SealExpand XTRA foam tape has outstanding expansion sealing and adapting to the gap and its movements. 

Prefabricated construction in concrete or other materials

Perimeter sealing of frames

Cladding panels

Façade joints, namely between cladding panels or around windows/doors, are often sealed to avoid water ingress, heat loss and promote acoustic insulation. 

Effisus Sealexpand XTRA foam tape delivers exceptional expansion capacity, adapting to irregular gap shapes and accommodating joint movements with lasting elasticity. This ensures durable watertightness along with reliable thermal and acoustic performance. Resistant to UV exposure and direct rain, it acts as a standalone sealing system that is quick to install, maintenance-free, and suitable for various construction methods, including general building, timber or steel frames, and modular projects, both new and refurbished. 

Moreover, Effisus Sealexpand XTRA is also used to close off the end of roofing sheets, as an alternative to profiled foam fillers, and thus seals these edges on metal roofs. 

For cases of demanding façade interfaces with more demanding requirements, such as extreme elongation and fire resistance ability, Effisus ProFlex FR high-performance weatherproofing membrane would be a perfect fit. 

PropertyStandardValue
Joint permeability (a-value)DIN EN 12114a ≤ 0.1 m³/ (h.m.(daPa)n)
Air tightnessDIN EN 12114a ≤ 0.1 m³/ (h.m.(daPa)n)
Driving rain resistanceDIN EN 1027DIN 18542 BG1 ≥ 600 Pa
Temperature-change resistanceDIN 18542 BG1 -20ºC to +80ºC
Compatibility with other building materialsDIN 18542 BG1Requirements fulfilled
Construction material class / reaction to fireDIN 4102-1B1 (low flammability) ABP-No. P-NDS04-850
Water vapour permeability, sd-valueEN ISO 12572< 0.5m
Thermal conductivity DIN 52612λ = 0,046 W/(m·K)
Heat transfer coefficient at a tape width of 75 mmDIN EN 12667U-value = 0.56 W/(m2·K)
Technical Data Sheet
Installation Manual
Effisus
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.